You check it yourself first
Reset the breaker, swap the thermostat batteries, check the outdoor disconnect is pushed in. If one of those was the problem, the heat pump starts right back up.
Tell a local repair pro what your heat pump is doing.
Get matchedA heat pump that won't turn on is usually stuck on a lockout or starved of power. Thermostat batteries die, a breaker trips, or the outdoor disconnect gets bumped and the system reads it as no call for heat at all. In Delaware, where most houses heat with gas and lean on the heat pump mainly to cool through the sticky summer months, a unit that's sat idle can also trip a safety switch meant to protect the compressor, and it won't restart until that switch is reset or cleared. Sometimes the fix is as small as flipping a breaker back. Other times the outdoor unit itself has failed to get power, or a control board inside has shut the system down on purpose because it sensed something wrong. Either way, running the unit blind, by cycling the breaker over and over, risks turning a small electrical fault into a damaged compressor. Catching it early, before it sits dead for days, usually means a shorter repair.

The outdoor unit holds the compressor and the reversing valve, and it has to run for the indoor air handler to push out warm air. If the breaker for the outdoor unit trips, or a service disconnect near the unit gets pulled or knocked loose, the indoor blower may still light up and act normal while nothing happens outside. Check that disconnect before you assume the whole system is dead.

A lockout is the control board protecting the compressor from a problem it already detected, like a pressure switch trip or too many short cycles in a row. It will not let the unit restart until power is cut and restored, which is why flipping the breaker off for a minute and back on clears some no-start calls. If it locks out again right away, something upstream is still tripping it.
You walk to the thermostat and nothing happens when you bump the temperature. No fan noise from the air handler, no hum from the outdoor unit. Maybe the thermostat screen itself is blank. Maybe it lights up fine but the system never responds, no click, no whoosh of air from the vents. Outside, the unit sits silent and cold to the touch, no vibration, no airflow off the top. If you've already checked the breaker and the thermostat batteries and still have nothing, the delay matters. Most Delaware homes lean on gas for heat and the heat pump handles the in-between months, but if yours is the main source and it sits dead through a cold stretch, the house loses ground fast, and power here isn't cheap to make up with space heaters.

It's past midnight and the sheets are stuck to your back. You kicked off the blanket an hour ago and it didn't help. The window's fogged up at the edges from the air conditioner down the hall fighting the same humidity that's beat every August you can remember in Delaware. You get up and check the thermostat again, same as the last two times. Still nothing. No click from the hallway vent, no hum from outside. You stand there a second longer than you need to, then go back and lie down on the dry side of the pillow, waiting for the room to cool on its own.


The thermostat doesn't power your heat pump directly. It sends a low-voltage signal to a contactor in the outdoor unit, and that contactor has to close before the compressor gets any power at all. If it's pitted or stuck, the thermostat can be working fine and the unit still won't make a sound. Cold snaps add another step. The system runs a defrost cycle to clear ice off the outdoor coil, and if the control board gets stuck partway through that cycle, the unit can sit idle long after the ice is gone. The reversing valve is in the middle of all this too, switching the system between heating and cooling, and a valve stuck in the wrong spot can make the unit act like it never got a call for heat in the first place. Low-voltage wiring runs through all of it on a 24-volt transformer, and a short there can blow a fuse on the board and cut power to the whole system. Even the backup heat strips in the air handler can trip a limit switch that blocks the heat pump from starting.



Your request stays with one local pro.
Describe your heat pump job, and a local pro who handles it gets in touch.
Sending the form costs nothing.




Reset the breaker, swap the thermostat batteries, check the outdoor disconnect is pushed in. If one of those was the problem, the heat pump starts right back up.
A pitted contactor, a tripped high-pressure lockout, or a failed control board won't clear on their own. That calls for a licensed Delaware contractor who works on heat pumps all winter.
You've already reset the breaker and checked the thermostat batteries, so now you want to understand the sequence behind the failure instead of just guessing again. Knowing what usually goes first, and what that failure causes next, helps you describe the problem clearly if you end up needing someone to look at it.
The thermostat sends a low-voltage signal first. If that signal doesn't reach the outdoor unit, nothing downstream ever gets a chance to work. Next in line is the contactor, the switch that closes to send full power to the compressor. A contactor with pitted contacts can get the signal but fail to close, so the outdoor unit stays silent even though the thermostat is calling for heat. Only after power actually reaches the compressor does a bad capacitor or a locked rotor come into play, and those tend to show up as humming rather than total silence. Power problems in Delaware, where a tripped breaker or a bumped disconnect is common, show up as complete silence. A compressor problem usually sounds like something trying and failing to start.

Summer air in Delaware carries a dew point that averages 65°F across June, July and August, according to NOAA climate data. Air that heavy makes a heat pump's outdoor coil work against moisture as much as heat, and in cooling mode that moisture has to condense off before the system feels like it's making progress. If the coil is already dirty or the system is low on charge, that extra load is what pushes it into a high pressure lockout instead of just running longer. You'll notice it as a unit that seems to try, short cycles, then goes quiet rather than one that never responds at all.
NASA POWER T2MDEW county cells weighted by homes

The pad is clear and the fan grille is clean. The disconnect box on the wall is seated tight, and the lines running to it show no rust or wear. A unit kept like this starts as soon as the thermostat calls for it.

Rust has worked into the top grille and dirt has built up around the base. Corrosion like that reaches the contactor and the wiring inside, and a unit in this shape is the one that trips a breaker or stalls out instead of starting.
At that rate, a heat pump that short cycles or runs its backup heat strips every time it fails to start adds up fast on your bill. It's part of why a lockout you catch in week one is worth more here than in states with cheaper power.
EIA-861 2025 statewide residential average
Thermostat sends a low-voltage call for heat to the outdoor unit.
The contactor in the outdoor unit closes to send it power.
The compressor and outdoor fan start together.
A control board checks pressures before letting the system keep running.

A heat pump that won't turn on almost always comes down to one of a handful of things: a tripped breaker, dead thermostat batteries, a disconnect that got bumped, or a contactor that's worn out from doing its job too many times. None of that means the system is failing. It means something in the chain between the thermostat and the compressor needs attention before the next cold night in Delaware catches you off guard.
If you've gone through the checks and the unit still won't start, the next step is getting someone who works on heat pumps in Delaware every winter to look at the contactor, the pressure switches, and the wiring behind the disconnect. You'll be matched with one licensed local contractor, not a list of them, so you're not fielding five calls to find out which one actually knows your equipment. That one contractor reaches out to you directly.


Get your heat pump to the right pro